Watts to Amps Converter

Watts ↔ amps for DC, AC single-phase and three-phase — with power factor handled properly — plus a complete Ohm’s law calculator below.

Flat vector illustration for the Watts to Amps Converter
Result
—

The whole picture

Ohm’s Law Calculator

Enter any two values — voltage, current, resistance or power — and the other two are worked out for you.

All four values
—

The quick answer

Converting watts to amps needs one more ingredient: voltage. Amps are the flow, volts are the pressure, watts are the result of the two together:

Amps = Watts ÷ Volts  (DC)  ·  Amps = Watts ÷ (Volts × PF)  (AC single-phase)  ·  Amps = Watts ÷ (√3 × Volts × PF)  (AC three-phase)
1,200 W at 120 V10 A (DC)

A US space heater on its own circuit maths.

1,200 W at 120 V AC11.1 A

With a typical 0.9 power factor.

10 kW at 400 V 3-phase17 A

PF 0.85 — industrial motor territory.

100 W at 12 V8.3 A

Why car and solar wiring is so thick.

Watts to amps at common voltages (DC / resistive load)

Watts12 V24 V120 V230 V240 V
100 W8.33 A4.17 A0.83 A0.43 A0.42 A
250 W20.8 A10.4 A2.08 A1.09 A1.04 A
500 W41.7 A20.8 A4.17 A2.17 A2.08 A
1,000 W83.3 A41.7 A8.33 A4.35 A4.17 A
1,500 W125 A62.5 A12.5 A6.52 A6.25 A
2,000 W166.7 A83.3 A16.7 A8.70 A8.33 A
3,000 W250 A125 A25 A13.0 A12.5 A

For AC appliances with motors or electronics, divide by the power factor as well — the converter above does it automatically when you pick an AC mode.

Power factor, in plain words

In DC and simple resistive AC loads (heaters, kettles, incandescent bulbs), volts and amps work in perfect step and Watts = Volts × Amps. Motors, compressors and many power supplies make the current lag behind the voltage — the power factor (0 to 1) measures how far out of step they are. The load still draws the full current, so cables and breakers must be sized on the higher amps figure: that’s why the same 1,200 W needs 10 A on paper but 11.1 A at PF 0.9. Nameplates often print the amps directly — trust that number over any conversion.

Common mistakes to avoid

  • Converting watts to amps without a voltage. It’s impossible — 100 W is 8.3 A at 12 V but 0.43 A at 230 V. Any answer that skips voltage is a guess.
  • Sizing a breaker to the exact load. Continuous loads should use at most 80% of a breaker’s rating: a 12.5 A heater belongs on a 20 A circuit, not a 15 A one that’ll nuisance-trip.
  • Using single-phase math on three-phase kit. The √3 factor changes the answer by 73%. Check the nameplate for “3~” before calculating.
  • DIY beyond your depth. Conversions are fine on paper; wiring changes are licensed-electrician territory in most places. Know where the line is.

Pro tips

  • Solar & RV math: at 12 V, every 100 W is roughly 8.3 A — use it to sanity-check cable sizes and fuse ratings before you buy.
  • The Ohm’s law wheel: V = I × R, P = V × I. With any two of the four values, the calculator above derives the rest — including the √ forms like V = √(P × R).
  • kW and kVA: for generators, kVA × PF = kW. A 10 kVA generator at PF 0.8 delivers 8 kW of real power — plan loads against the kW figure.

The complete guide

Volts, amps, watts and ohms trip up everyone because they’re invisible. The complete guide builds the water-pipe picture properly, then walks through breaker sizing, solar math and the three-phase formulas.

Read: Watts to Amps Converter — The Complete Guide →

Frequently asked questions

How do I convert watts to amps?

Divide watts by volts: Amps = Watts ÷ Volts. For AC circuits, also divide by the power factor — and for three-phase, by √3 as well. Example: 1,200 W at 120 V DC is 10 A; the same load on AC single-phase with PF 0.9 draws 11.1 A.

How many amps is 1,500 watts?

At 120 V: 12.5 A (DC/resistive). At 230 V: 6.5 A. At 12 V: 125 A — which is why a 1,500 W inverter needs very thick cables. Voltage is everything in this conversion.

What is power factor and why does it matter?

Power factor (0–1) describes how efficiently an AC load uses current. Motors and electronics often run at 0.8–0.95. A lower power factor means the same watts need more amps, so cables, breakers and generators must be sized for the higher current. Resistive loads like heaters have PF = 1.

What is the three-phase amps formula?

Amps = Watts ÷ (√3 × line voltage × power factor). Example: a 10 kW motor on 400 V three-phase with PF 0.85 draws 10,000 ÷ (1.732 × 400 × 0.85) ≈ 17 A per phase.

What is Ohm’s law?

Ohm’s law ties voltage, current and resistance together: V = I × R. Combined with P = V × I, any two known values give you the other two — for example 12 V across 4 Ω means 3 A and 36 W. The second calculator on this page does all twelve combinations.

Can I convert amps to watts without knowing voltage?

No — and neither can anyone else. Watts are volts × amps, so without the voltage the answer can be anything. If a device only lists amps, find its voltage on the nameplate (mains, battery or USB) and the conversion becomes exact.